HEGER POWER – Auxiliary Systems
Lube Oil Systems (non API)
Lube oil capacity to 950 gpm (3,500 l/min) Pressure to 450 psig (30 barg) Shell & tube, plate, or fin fan oil cooler.![](https://hegerpumps.com/wp-content/uploads/2019/11/Heger-Lube-Oil-System05-1024x598.png)
![](https://hegerpumps.com/wp-content/uploads/2019/11/Heger-Lube-Oil-System07-e1573507821147.png)
![](https://hegerpumps.com/wp-content/uploads/2019/11/Heger-Lube-Oil-System06-1024x771.png)
Lube Oil System (API)
Lube Oil Unit acc. to API with air cooled oil-cooler (blower 3x50%)![](https://hegerpumps.com/wp-content/uploads/2019/11/Heger-API-Lube-Oil-Air-Cooler01-225x300.png)
![](https://hegerpumps.com/wp-content/uploads/2019/11/Heger-API-Lube-Oil-System02-300x202.png)
![](https://hegerpumps.com/wp-content/uploads/2019/11/Heger-Power-Logo-2019-e1573504845755-300x66.png)
- Element heat exchangers (plain, fin, lamella tube)
- Shell & Tube heat exchanger
- Plate heat exchanger
- Turbine oil cooling systems
- Pure water units for generators and rectifiers
- Other cooling units with above mentioned heat exchangers
- Related technical apparatus & aggregates
- Safety heat exchangers
- Maintenance for all our products and systems
- carbon and alloy steels
- fine grain structural steel
- Stainless Steel
- Nickel based alloys
- copper and copper based
- titanium
- plated steel
- aluminum and aluminum alloys
- copper nickel alloys
- plastics
![](https://hegerpumps.com/wp-content/uploads/2019/11/Heger-Power-Logo-2019-e1573504845755-300x66.png)
![](https://hegerpumps.com/wp-content/uploads/2019/11/Stamps-300x76.png)
- ISO 9001:2015 valid to 2021 (since 1995)
- QA system to Directive 2014/68/EU
- ASME U Certificate of Authorization
- The National Board of Boiler & Pressure Vessel Inspectors (NB mark - ASME U)
- Calculations acc to ASME VIII / EN 13445-3 / AD 2000 / TEMA
- Manufacturing to ASME U STAMP / PED 97/23/EC / UDT
- M-SYSTEM by DIN EN ISO 9001:2008 (TÜV certified)
Fuel Gas Systems
Fuel Gas Systems with insulation![](https://hegerpumps.com/wp-content/uploads/2019/11/Heger-Fuel-Gas-System01-300x263.png)
![](https://hegerpumps.com/wp-content/uploads/2019/11/Heger-Fuel-Gas-System02-300x283.png)
Fuel Oil Systems
Fuel oil systems with filter and control valvesSeal Oil Skids
Seal oil to 111 gpm (420 l/min) Pressures to 217 psig (15 barg)
![](https://hegerpumps.com/wp-content/uploads/2019/11/Heger-Seal-Oil-Skid01-1024x758.png)
![](https://hegerpumps.com/wp-content/uploads/2019/11/Heger-Seal-Oil-System-Generator-Hydrogen-Cooled01.png)
![](https://hegerpumps.com/wp-content/uploads/2019/11/Heger-Seal-Oil-System-Generator-Hydrogen-Cooled02.png)
Seal Gas Systems
Seal Gas Systems for multistage, gas lubricated mechanical shaft seals![](https://hegerpumps.com/wp-content/uploads/2019/11/Heger-Seal-Gas-System-Gas-Lubricated-Mech-Seals01-1024x685.png)
Wet Compression Skids
Seal Air Coolers
![](https://hegerpumps.com/wp-content/uploads/2019/11/Heger-Seal-Oil-Cooler01.png)
![](https://hegerpumps.com/wp-content/uploads/2019/11/Heger-Seal-Oil-Cooler-VFD-Junction-Box01-300x254.png)
![](https://hegerpumps.com/wp-content/uploads/2019/11/Heger-Seal-Oil-Cooler-Fan-Maintenance-02-300x255.png)
Steam Gland Condensers - API & Custom
![](https://hegerpumps.com/wp-content/uploads/2019/11/Heger-Gland-Steam-Condenser05-253x300.png)
![](https://hegerpumps.com/wp-content/uploads/2019/11/Heger-Gland-Steam-Condenser04-225x300.png)
![](https://hegerpumps.com/wp-content/uploads/2019/11/Heger-Gland-Steam-Condenser03.png)
![](https://hegerpumps.com/wp-content/uploads/2019/11/Heger-Gland-Steam-Condenser02-300x236.png)
![](https://hegerpumps.com/wp-content/uploads/2019/11/Heger-Gland-Steam-Condenser01-300x236.png)
![](https://hegerpumps.com/wp-content/uploads/2019/11/Heger-API-Gland-Steam-Condenser01.png)
![](https://hegerpumps.com/wp-content/uploads/2019/11/Heger-API-Gland-Steam-Condenser04-300x225.png)
![](https://hegerpumps.com/wp-content/uploads/2019/11/Heger-API-Gland-Steam-Condenser03-300x200.png)
![](https://hegerpumps.com/wp-content/uploads/2019/11/Heger-API-Gland-Steam-Condenser02-300x200.png)
Air-Water & Air-Air Cooling Systems
Air to Air cooling System![](https://hegerpumps.com/wp-content/uploads/2019/11/Heger-Air-to-Air-Cooling-System01-e1573510678316.png)
![](https://hegerpumps.com/wp-content/uploads/2019/11/Heger-Air-Water-Cooling-System01-e1573510700335.png)
Tube Bundle & Lamella Tube Heat Exchangers
![](https://hegerpumps.com/wp-content/uploads/2019/11/Heger-Fixed-Tube-Bundle01-300x164.png)
![](https://hegerpumps.com/wp-content/uploads/2019/11/Heger-Fixed-Tube-Bundle02-300x242.png)
![](https://hegerpumps.com/wp-content/uploads/2019/11/Heger-Fixed-U-Tube-Bundle01-300x225.png)
![](https://hegerpumps.com/wp-content/uploads/2019/11/Heger-Lamella-Tube-heat-Exchanger-Removable-headers01-178x300.png)